Connecting Procedure For Op Panel - Ricoh D009 Service Manual

Hide thumbs Also See for D009:
Table of Contents

Advertisement

1.5 CONNECTING PROCEDURE FOR OP PANEL

1. Route and attach the operation
panel I/F cable to the outside of
the scanner right frame with
four plate clamps (
- tapping M3x8).
NOTE: Make sure that the operation panel I/F cable [A] does not cover the
three cutouts [B].
2. Connect the harness [2] to the
operation panel interface board
[3] as shown.
B838
x 4; screw
20
Connecting Procedure for Op Panel
B838R934.PNG
B838R928.PNG
B838R929.PNG
SM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents