Rev. 03/09/2012
013 Duplex Left: Thick
014 Duplex Right: Thick
LD Power Adjustment
2105*
Adjusts the LD power for each mode.
Each LD power setting is decided by the process control.
⇒
001 LD1: Copy
002 LD2: Copy
⇒
003 LD1: Printer/Fax
004 LD2: Printer/Fax
2106*
POL REV TIME (Polygon motor rotation time)
PRE TIME
001
Adjusts the time of polygon motor rotation before a job.
If this is set to "0", this SP is not activated.
POST TIME
Adjusts the time of the polygon motor rotation after a job.
002
If this is set to "0", the polygon motor never switches off in standby mode.
However, if the machine enters the energy saver mode, the polygon motor
will ignore the zero setting and switch itself off.
SM Appendix
[0 to 1.5 / 0.1 / 0.1mm]
[–50 to 79 / -24 (D009/D011),
5 (D012/D013/D091/D092) /1 ]
[–50 to 79 / -44 (D009/D011),
-25 (D012/D013/D091/D092)/1 ]
[0 to 60 / 10 /1 sec]
[0 to 60 / 0 /1 sec]
4-21
D009/D011/D012/D013/D091/D092
System SP Table-2