MAINTENANCE DATA PROGRAMMING
START
CM08
Define fault information to be stored.
Specify the processing at the time of the fault
information memory overflow.
CMEA
Assign the registration of fault information
into memory and the control of the external
alarm.
END
DESCRIPTION
CHAPTER 3 SYSTEM DATA PROGRAMMING
MAINTENANCE DATA PROGRAMMING
(1)
450
(2)
1 : To store
(1)
451
(2)
0 : No fault information is registered
1 : Fault information is overwritten
•
Y=2
(1)
12 : CS fault occurred
2B: CS fault occurred
3B: CS fault recovered
(2)
0: Registration of fault memory/No output
of External alarm
1: Registration of fault memory/External
alarm is MN alarm
2: Registration of fault memory/External
alarm is MJ alarm
3: Registration of fault memory/External
alarm kind is determined in standard data
NONE : No Registration of fault memo-
– 155 –
DATA
ry/No output of external alarm
NWA-008855-001 Rev.1.0
avch3001.fm