Derate maximum dry bulb temperature 1 degree / 300 meters above 900 meters.
Table 20 Physical and Environmental Specifications of the Office Friendly Server
Typical Heat Release
100-127
VAC
Watts
Watts
Minimum
363 W
363 W
Config.
Maximum
782 W
782 W
Config.
Typical
483 W
483 W
Config.
ASHRAE
Airflow cooling scheme (front to rear)
Class 1
1
Derate maximum dry bulb temperature 1 degree / 300 meters above 900 meters.
Condition
Nominal Airflow
200-240
VAC
CFM
m3/hr
45
76
45
76
45
76
Weight
Maximum
Airflow @ 35
1
Server
degrees C
CFM
m3/hr
21 kg -
28 kg (46
162
275
lb - 61 lb)
162
275
162
275
Min
Two 4 GB DDR2 DIMMs, no PCIe/PCI-X
Config
public cards or, RAID card on private
I/O slot.
Max
Eight 4 GB DDR2 DIMMs, three
Config
PCIe/PCI-X cards on public I/O slots,
and RAID card in private slot.
Typical
Four 4 GB DDR2 DIMMs, one
Config
PCIe/PCI-X card on public I/O slots,
and RAID card in private slot.
Physical and Environmental Specifications
Server
Dimensions
Pedestal
Pedestal
30 kg -
D 69 cm W 27.6
37 kg
cm (with feet) W
(66 lb -
12.7 cm (w/o
81 lb)
feet) H 50.8 (D
27.2 in W 10.8
in (with feet) W
5.0 in (w/o feet)
H 20.0 in)