Cooling; Data Center Server Cooling - HP Integrity rx2660 User's & Service Manual

Hide thumbs Also See for Integrity rx2660:
Table of Contents

Advertisement

FIRMWARE INFORMATION
*System Firmware A Revision: 3.02 [4819]
System Firmware B Revision: 3.02 [4819]
BMC Revision: 5.20
Management Processor Revision: T.02.17
Updatable EFI Drivers:
Floating Point Software Assistance Handler: 00000118
Broadcom Gigabit Ethernet Driver: 00090404
SCSI Bus Driver: 00000031
SCSI Disk Driver: 00000020
SCSI Tape Driver: 00000030
Usb Ohci Driver: 00000040
USB Bus Driver: 00000020
USB Bot Mass Storage Driver: 00000020
Generic USB Mass Storage Driver: 00000020
CLPrelay App: 00000100
* Indicates active system firmware image. In this case =>3.02 indicates that this server does not
need system firmware updated to use the memory modules described in this document.
The firmware upgrade instructions are included in the Release Notes on the firmware package
download page for your server product. To locate the Release Notes and download the firmware:
1.
Go to http://www.hp.com/bizsupport.
2.
Select Download Drivers and Software.
3.
Select HP Integrity Servers.
4.
Select the link for your server product.
After the firmware has been downloaded, you can install the memory. To install DIMMs, see
"Installing Memory" (page

Cooling

Data Center Server Cooling

Twelve fans cool the Data Center server. The fans are all redundant, hot-swappable, and
interchangeable. Eight fans cool the eight DIMMs and two processors. Four fans cool the hard-disk
drives and the PCI riser board. The fans cool three zones in the server. Fans 1 through 4 cool Zone
1, fans 5 through 8 cool Zone 2, and fans 9 through 12 cool Zone 3. Each zone can run with
one fan failure. The other fans in the zone increase speed to compensate for the fan failure. The
fans are N+1 per zone, meaning that the server has 12 fans, but can operate with 9 fans running
(one fan failure per zone). See
zones.
The power supplies have built-in fans and are not controlled by the Baseboard Management
Controller (BMC).
170).
Figure 43 (page 146)
for the Data Center fan locations and cooling