2.
If rack mounted, slide the server completely out from the rack. See
the Rack" (page
141).
3.
Remove the top cover. See
4.
Disconnect the internal SAS cables attached to the board. See
CAUTION:
When disconnecting the SAS cables, note the labeling on the cables. When
reconnecting these cables, match each cable with the appropriate socket on the Smart Array
P400 controller. If the cables are mismatched, the server might not reboot. Both cables and
sockets are clearly marked with the correct channels.
Figure 79 Smart Array P400 Controller Location on System Board
RAID battery port on
1
the SAS Smart Array
P400 controller
SAS cable ports on
2
the SAS Smart Array
P400 controller
5.
Disconnect the battery cable from the Smart Array P400 controller card.
6.
Grasp the card by the edges and lift it out of the server.
Removing and Replacing the Smart Array P400 Controller and PCIe Expansion Board 189
"Removing the Top Cover" (page
SAS Smart Array
3
P400 controller
"Extending the Server from
142).
Figure
79.
SAS Smart Array P400
4
controller board lock