ACX1000 and ACX1100 Universal Access Router Hardware Guide

Grounding Cable Lug Specifications

122

Figure 33: Grounding Points on the ACX1000 and ACX1100 Router

ACX1000
MGMT
ALARM
CONSOLE/AUX
SYS
0
1
1— Grounding points
NOTE:
All bare grounding connection points to the router must be cleaned
and coated with an antioxidant solution before grounding the router.
NOTE:
All surfaces on the router that are unplated must be brought to a
bright finish and treated with an antioxidant solution before connecting the
router.
NOTE:
All nonconductive surfaces on the router must be removed from all
threads and connection points to ensure electrical continuity.
The grounding cable lug is used to secure the grounding cable to the grounding points
on the ACX chassis. The grounding cable lug attaches to the grounding cable (see
34 on page
122) and is secured to the router by two SAE 10–32 screws. We recommend
using paint-piercing washers between the grounding lug and the screws. The grounding
cable lug, screws, and washers are not supplied with the router.

Figure 34: Grounding Cable Lug

1.69
End view
0.2
0.38
dia.
0.06
0.625
CAUTION:
Before router installation begins, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with
an incorrectly attached lug can damage the router.
T1/E1
GE
0/0/4
0/0/5
0/0/6
0/0/7
0/1/4
0/1/5
0/1/6
1PPS
10MHz
IN
OUT
IN
OUT
0/0/0
0/0/1
0/0/2
0/0/3
0/1/0
0/1/1
0/1/2
6 AWG conductor
All measurements in inches
0/1/7
0/2/2 (Cu)
0/2/3 (Cu)
0/2/0 (SFP)
0/2/1 (SFP)
0/2/2 (SFP)
0/2/3 (SFP)
0/1/3
0/2/0 (Cu)
0/2/1 (Cu)
COMBO PORTS
Copyright © 2013, Juniper Networks, Inc.