Juniper ACX1000 Hardware Manual page 148

Universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

ACX1000 and ACX1100 Universal Access Router Hardware Guide
Table 27: Alarm Contact Connector Pinouts (continued)
Pin
Number
Signal Definition
4
ALARM_IN3_NO/NC
5
ALARM_OUT3_REF
6
ALARM_IN0_REF
7
ALARM_IN1_NO/NC
8
ALARM_IN2_IN3_REF
9
ALARM_OUT2_REF
10
ALARM_OUT3_NO/NC
11
ALARM_OUT0_NO/NC
12
ALARM_OUT0_REF
13
ALARM_OUT1_NO/NC
14
ALARM_OUT1_REF
15
ALARM_OUT2_NO/NC
Related
Documentation
132
Direction
CLI Port Mapping
Input
Input Alarm Port 3
Output
Reserved for Minor
alarm
Input
Input Alarm Port 0
Input
Input Alarm Port 1
Input
Input Alarm Port 2 and
Input Alarm Port 3
Output
Reserved for Major
alarm
Output
Reserved for Minor
alarm
Output
Output Alarm Port 0
Output
Output Alarm Port 0
Output
Output Alarm Port 1
Output
Output Alarm Port 1
Output
Reserved for Major
alarm
ACX1000 and ACX1100 Universal Access Router Overview on page 3
Front Panel of an ACX1000 Router on page 9
LEDs on ACX1000 and ACX1100 Routers on page 12
Alarm Contact Port on ACX1000 and ACX1100 Routers on page 18
Function
External alarm input 3 (if voltage on this pin is
between 24V to 72V with reference to Pin 8,
alarm input 3 is in closed condition)
External alarm output 3 (this pin is connected
to Pin 10 in closed condition)
External alarm input 0 (Reference for Pin 1)
External alarm input 1 (if voltage on this pin is
between 24V to 72V with reference to Pin 2,
alarm input 1 is closed)
Common contact for external alarm input 3 and
4 (Reference for Pin 3 and Pin 4)
External alarm output 2 (this pin is connected
to Pin 15 in closed condition)
External alarm output 3 (this pin is connected
to Pin 5 in closed condition)
External alarm output 0 (this pin is connected
to Pin 12 in closed condition)
External alarm output 0 (this pin is connected
to Pin 11 in closed condition)
External alarm output 1 (this pin is connected
to Pin 14 in closed condition)
External alarm output 1 (this pin is connected
to Pin 13 in closed condition)
External alarm output 2 (this pin is connected
to Pin 9 in closed condition)
Copyright © 2013, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx1100

Table of Contents