Juniper ACX1000 Hardware Manual page 146

Universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

ACX1000 and ACX1100 Universal Access Router Hardware Guide
Related
Documentation
130
P
= P
– LL
M
B
P
= 13 dB – 2 km (1.0 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB [HOL] – 1 dB [CRM]
M
P
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB – 1 dB
M
P
= 6 dB
M
The following sample calculation for an 8-km-long single-mode link with a power budget
(P
) of 13 dB uses the estimated values from
B
(LL) as the sum of fiber attenuation (8 km @ 0.5 dB/km, or 4 dB) and loss for seven
connectors (0.5 dB per connector, or 3.5 dB). The power margin (P
follows:
P
= P
– LL
M
B
P
= 13 dB – 8 km (0.5 dB/km) – 7(0.5 dB)
M
P
= 13 dB – 4 dB – 3.5 dB
M
P
= 5.5 dB
M
In both examples, the calculated power margin is greater than zero, indicating that the
link has sufficient power for transmission and does not exceed the maximum receiver
input power.
Supported Network Interface Standards by Transceiver