Understanding Alarm Types and Severity Classes on ACX Series Routers

Alarm Types

Alarm Severity Classes

64
Link LEDs—Each network port has one pair of port LEDs that indicate the status of the
ports.
For more information on front panel LEDs, see
on page
12.
Understanding Alarm Types and Severity Classes on ACX Series Routers on page 64
Verifying Active Alarms on page 65
Monitoring System Log Messages on page 66
Before monitoring alarms on the router, become familiar with the terms defined in
19 on page
64.

Table 19: Alarm Terms

Term
Definition
alarm
Signal alerting you to conditions that might prevent normal operation.
On a router, the alarm signal is the red system LED lit on the front of the
chassis.
alarm condition
Failure event that triggers an alarm.
alarm severity
Seriousness of the alarm. The level of severity can be either major
(steady red) or minor (blinking red).
chassis alarm
Predefined alarm triggered by a physical condition on the router, such
as a power failure, excessive component temperature, or media failure.
system alarm
Predefined alarm triggered by a missing rescue configuration or failure
to install a license for a licensed software feature.
The router supports these alarms:
Chassis alarms indicate a failure on the router or one of its components. Chassis alarms
are preset and cannot be modified.
System alarms indicate a missing rescue configuration. System alarms are preset and
cannot be modified, although you can configure them to appear automatically in the
J-Web interface display or CLI display.
Alarms on ACX Series routers have two severity classes:
Major (steady red)—Indicates a critical situation on the router that has resulted from
one of the following conditions. A red alarm condition requires immediate action.