Logging Out Of Airwave - Dell PowerConnect W-Airwave User Manual

W-airwave 7.3 user guide
Hide thumbs Also See for PowerConnect W-Airwave:
Table of Contents

Advertisement

which is affected by the total number of APs and by the amount of data being saved, especially client historical
data.
To restore the Watched AMP, run the backup script from the command line and copy the current data file and
the old Watched AMP configuration file to the Watched AMP. Then run the restore script. More information
about backups and restores can be found in
Table 125 Home > Watched Page Fields and Default Values
Setting
IP/Hostname
Username
Password
HTTP Timeout
(5-1000 Sec)
Polling Enabled
Polling Period
Missed Poll
Threshold

Logging out of AirWave

To log out of AirWave, select the Logout link on the upper right hand corner of every AirWave page.
You will be logged off automatically based on the number of minutes set in the AMP User Idle Timeout setting
of AMP Setup > Authentication. Refer to
Authentication" on
Dell PowerConnect W-AirWave | User Guide
"Backing Up AirWave" on page
Default
Description
None
The IP address or Hostname of the watched AMP.
The Failover AMP needs HTTPS access to the watched AMPs.
None
A username with management rights on the watched AMP.
None
The password for the username with management rights specified above.
60
The amount of time before AMP considers a polling attempt failed.
Yes
Enables or disables polling of the Watched AMP.
NOTE: You do not need to disable polling of the watched AMP system if it is set to be down
during nightly maintenance or is being upgraded.
5 minutes
The amount of time between polls of the Watched AMP.
None
The number of polls that can be missed before the failover AMP will begin actively monitoring
the Watched AMP APs.
"Configuring Timeout, Login Message, TACACS+ and RADIUS
page 48.
221.
Performing Daily Administration in AirWave | 223

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerconnect w-airwave 7.3

Table of Contents