Barco ScreenPRO-II User Manual page 119

Hide thumbs Also See for ScreenPRO-II:
Table of Contents

Advertisement

pÅêÉÉåmolJff=dÉåäçÅâ=qÉêãáå~íáçå=jÉåì
After having configured a wide screen destination, the ScreenPRO-II Genlock
Termination Menu will automatically appear if the system senses that any of the
termination switches (in the Widescreen Lock signal chain) are improperly set.
A sample ScreenPRO-II Genlock Termination Menu is shown below:
B
A
C
K
Figure 4-25. ScreenPRO-II Genlock Termination Menu
This menu provides important information about the current status of your system's
Widescreen Lock chain, and each ScreenPRO-II's Termination Switch .
To correct the error:
ScreenPRO-II Controller • User's Guide
Note
In Chapter 3, refer to the "
Connections
Widescreen Lock connection.
SP-II GENLOCK TERMINATION
Current Termination Status
SP 1: HI-Z
SP 3: 75 Ohm
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Set SP-II termination as follows:
Set to HI-Z: SP 3
Error: Termination setup incorrect
Press CHECK TERM to retest setting.
CHECK
MORE
TERM
Important
If you press
Termination Menu and the Destination Setup Menu will
endlessly loop — until the termination problem is fixed.
Review the menu information in detail.
Follow the instructions as noted in the menu to change the physical position of the
termination switch(es) as instructed. For information on the termination switch, in
Chapter 3 refer to the "
ScreenPRO-II Genlock Termination
{
}
Press
CHECK TERM
to re-test the settings.
{
}
If required, press
MORE
BlendPRO-II Widescreen Lock
" section on page 77 for instructions on proper
SP 2: HI-Z
SP 4: 75 Ohm
{
},
BACK
the ScreenPRO-II Genlock
for additional "help" menus.