HP IBASIC (SMPLSWP2)
Chapter 4
The following program specifies a start frequency and a frequency span to
continuously sweep from 1 kHz to 21 kHz. The program also queries the
start frequency, stop frequency, center frequency, and frequency span to
show the relationship between them. Using the flowchart as a guide, the
steps of this program are:
1. Select the Frequency Sweep Mode -
[SOURce:]FREQuency:MODE SWEep
2. Set the Start Frequency -
[SOURce:]FREQuency:STARt <
3. Set the Frequency Span -
[SOURce:]FREQuency:SPAN <
4. Set the Output Function -
[SOURce:]FUNCtion[:SHAPe] <
5. Set the Signal Amplitude -
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <
6. Place the AFG in the Wait-for-arm State -
INITiate[:IMMediate]
1
!RE-SAVE"SMPLSWP2"
2
!This program sweeps a sine wave from 1 kHz to 21 kHz by
3
!specifying a start frequency and a frequency span.
4
!
10
!Assign I/O path between IBASIC and the E1340A.
20
ASSIGN @Afg TO 80910
30
COM @Afg
40
!
50
!Set up error checking
60
ON INTR 8 CALL Errmsg
70
ENABLE INTR 8;2
80
OUTPUT @Afg;"*CLS"
90
OUTPUT @Afg;"*SRE 32"
100
OUTPUT @Afg;"*ESE 60"
110
!
120
!Call the subprogram which resets the AFG.
130
CALL Rst
140
!
150
!Set AFG parameters
160
OUTPUT @Afg;"SOUR:FREQ:MODE SWE;";!frequency mode
170
OUTPUT @Afg;":SOUR:FREQ:STAR 1E3;";!start frequency
180
OUTPUT @Afg;":SOUR:FREQ:SPAN 20E3;";!frequency span
190
OUTPUT @Afg;":SOUR:FUNC:SHAP SIN;"; !function
Continued on next page