CALibration[:DC]:BEGin

[:DC]:BEGin

Comments

[:DC]:POINt

Comments
144
HP E1340A Command Reference
CALibration[:DC]:BEGin
E1340A. It sets the HP E1340A up for the first of the measurements in the
procedure. See the " Calibration" section of the HP E1340A Service
Manual for detailed information on the use of this command.
Most of the HP E1340A's commands cannot be executed while
calibration is in progress. The
prematurely terminate the calibration procedure without affecting the
stored calibration constants.
Executable when initiated: No
Coupled command: No
Related commands:
*RST Condition: none
CALibration[:DC]:POINt <
DC calibration point, computes needed calibration constants, and sets up the
HP E1340A for the next measurement. Each calibration constant is checked
for validity when it is computed. When all measurements and computations
are completed, the constants are stored in the HP E1340A's non-volatile
calibration memory.
The
*RST
command should be sent after completing the calibration
procedure to restore normal operation.
See the " Calibration" section of the HP E1340A Service Manual for
detailed information on the use of this command.
Most of the HP E1340A's commands cannot be executed while
calibration is in progress. The
prematurely terminate the calibration procedure without affecting the
stored calibration constants.
Executable when initiated: No
Coupled command: No
Related commands:
*RST Condition: none
starts the DC calibration procedure for the HP
*RST
command may be used to
CALibration:DC:POINt
value
takes the measured value for the current
>
command may be used to
*RST
CALibration:DC:BEGin
Chapter 7