2810 Check_ready: !Monitors command and parameter execution
2820
REPEAT
2830
CALL Read_status(Pass_fail,Ready,Done)
2840
UNTIL Ready
2850 SUBEND
2860 !
2870 SUB Read_status(Pass_fail,Ready,Done)
2880 Read_status:!Subprogram which reads the arb's Status Register
2890
COM Base_addr
2900
Status=READIO(-9826,Base_addr+4)
2910
Ready=BIT(Status,0)
2920
Pass_fail=BIT(Status,2)
2930
Done=BIT(Status,7) AND Ready
2940
Qryrdy=BIT(Status,1) AND Done
2950 SUBEND