15. How to Use the Front Panel
Monitor Mode (EXECUTION display)
(5) Display of I/O Signal Status
Displays the control input and output signal to be connected to connector X4.
Use this function to check if the wiring is correct or not.
• Shift the flashing decimal point with
• Select In or Out by pressing
• Select the Pin No. to be monitored by pressing
Note
For detail of input/output signal, refer to P3-30 "Inputs and outputs on connector X4"
For detail of Error Code, refer to P.6-3 "Protective Function".
2-60
.....Active (This signal is valid)
.....Inactive (This signal is invalid)
Pin No.
.....Input signal
.....Output signal
.
(Right side of decimal point : Pin No. selection)
(Left side of decimal point : Input/Output Pin No. selection)
or
button.
.
(Lowest place Pin No.
of output signal)
(Highest place Pin No.
of input signal)