Read Out Of Output Signal - Panasonic MINAS A5-series Operating Instructions Manual

Minas a5-series ac servo motor and driver
Table of Contents

Advertisement

4. Communication
Details of Communication Command
command
mode
2
8
error code
bit7
6
0 : Normal
1 : Error
Data
bit7
6
For
In-speed
manufacturer's use
bit15
14
Excite motor
Control power
latch
bit23
22
Speed
Safety EDM
command
ON/OFF
bit31
31
For
For
manufacturer's use
manufacturer's use
alarm data
bit7
6
Overload
Fan
protection
alarm
bit15
14
For
For
manufacturer's use
manufacturer's use
• The table below shows the relation of the signals and actions.
Signal title
Servo-Ready
Servo-Alarm
Positioning completed
Mechanical brake released
Zero speed detection
Torque in-limit
At-speed (Speed arrival)
In-speed (Speed coincidence)
Full-closed positioning complete
Control regeneration brake
Control inrush suppression relay
Dynamic brake engagement
Control power latch
Excite motor
• Because of the internal logical data before output conversion, it does not directly correspond to the output signal to the
connector X5.
• Names and functions shown above are for MINAS-A5 (general-purpose model). Some of input signals will have
different meaning for different series.

• Read out of output signal

Reception data
0
axis
8
2
checksum
5
4
Command error RS485 error
5
4
Torque in-limit
Zero speed
detection
13
12
Dynamic brake
Control inrush
engagement
suppression relay
21
20
Alarm attribute
Speed in-limit
output
output
29
28
For
For
manufacturer's use
manufacturer's use
5
4
Encoder
Over-regeneration
communication
alarm
alarm
13
12
For
manufacturer's use
Servo-Not Ready
Normal
Positioning not completed
Mechanical brake engaged
Zero speed not detected
Torque not in-limit
Not at-speed(Speed not arrived)
Not in-speed(Speed not coincided)
Full-closed positioning not completed
Turn off regeneration Tr
Release inrush suppression relay
Dynamic brake released
Release power latch
Energize motor
8
3
2
3
2
Positioning
Mechanical
complete
brake released
(In-position)
11
10
Control
Full-closed
regeneration
positioning
brake
complete
19
18
2nd positioning
Positional
complete
command
(In-position)
ON/OFF
27
26
For
For
manufacturer's use
manufacturer's use
3
2
Encoder overheat
Lifetime
alarm
detection alarm
11
10
External scale
communication
alarm
0
Positioning in-complete
Mechanical brake released
Zero speed detected
In-speed (Speed coincided)
Full-closed positioning completed
Turn on regeneration Tr
Operate inrush suppression relay
Dynamic brake engaged
Power abnormal latching
Transmission data
7
axis
2
data L
data H
alarm data L
H
error code
checksum
1
0
1
0
Servo-Alarm
Servo-Ready
9
8
At-speed
For
manufacturer's use
17
16
Alarm output 2
Alarm output 1
25
24
For
For
manufacturer's use
manufacturer's use
1
0
For
Battery
manufacturer's use
alarm
9
8
Oscillation
External scale
detection
error alarm
alarm
1
At Servo-Ready
At Servo-Alarm
Torque in-limit
Speed arriving
Servo free
7-45
1
2
3
4
5
6
7