Setup Of Front Panel Lock - Panasonic MINAS A5-series Operating Instructions Manual

Minas a5-series ac servo motor and driver
Table of Contents

Advertisement

2
Preparation
Outline
To prevent operational error e.g. unintentional parameter modification, the front panel
may be locked.
Once locked, operations on the panel are limited as follows:
Monitor Mode
Parameter Set up Mode
EEPROM Write Mode
Auxiliary Function Mode
How to operate
• Related parameters
Parameter No.
Class
5
Lock and unlock can be made in one of two ways.
Procedure
Lock
Unlock
Note
For details of front panel lock release, refer to P.2-81.
2-56
15. How to Use the Front Panel
Setup of front panel lock
Mode
No limitation: all monitored data can be checked.
No parameter can be changed but setting can be checked.
Cannot be run. (No display)
Cannot be run except for "Release of front panel lock". (No
display)
Title
No.
35

Setup of front panel lock

Front panel
(1) Set Pr5.35 "Front panel lock" to 1, and writ the setting to EEPROM.
(2) Turn on power to the driver.
(3) The front panel is locked.
(1) Execute the auxiliary function
mode, front panel lock release
function.
(2) Turn on power to the driver.
(3) The front panel is unlocked.
Locked panel conditions
Function
Locks the operation attempted from the front
panel.
Setup support software
PANATERM
(1) Set Pr5.35 "Front panel lock" to 0,
and writ the setting to EEPROM.
(2) Turn on power to the driver.
(3) The front panel is unlocked.

Hide quick links:

Advertisement

Table of Contents
loading