Junction Cable For Motor - Panasonic MINAS A5-series Operating Instructions Manual

Minas a5-series ac servo motor and driver
Table of Contents

Advertisement

5. Installation
Driver
<Supplement>
• The current correction coefficient is determined using the following formula:
(Max. permissible temp. – ambient temp.) ÷ 30
The current correction coefficient is determined according to the cable. Check the specifi-
Caution
cation of the cable used.
• The current reduction coefficient is provided for the
case where the cable (-conductor cable in the case of
example), is housed in plastic race/sheath, plastic tube,
metal race/sheath, metal tube or flexible conduit.
Caution
Because the neutral conductor is not counted as a wire, the
current reduction coefficient for "3 or less" is applied as indi-
cated by ( ) in the table right.
• Recommended eco-cable
Wire category: -conductor polyethylene-insulated power cable with heat-resistant
polyethylene sheath (Standard: EM JIS C 605)
Maximum permissible temperature: 90°C
Conductor
Nominal
Structure
Outside
cross
or
diameter
section
shape
(mm)
(mm
)
(wires/mm
)
2
2
2
7/0.6
1.8
3.5
7/0.8
2.4
5.5
7/1.0
3.0
8
7/1.2
3.6
Circular
14
4.4
compression
Circular
22
5.5
compression
Circular
38
7.3
compression
Shield will increase finish outside diameter by approx. 1 mm.
Caution
• Appropriate cable should be selected to have sufficient allowance for parameters such
Note
as operating ambient temperature and current.
• Current reduction coefficient, fundamental permissible current, etc., stated on this page
are subject to change due to e.g. standard revision. Consult cable manufacturers for
the latest information.
Related page
• P.1-15 "Junction cable for motor"
Insulation
Sheath
(Reference)
thickness
thickness
Finish O.D.
(mm)
(mm)
(mm)
0.8
1.5
12.0
0.8
1.5
13.5
1.0
1.5
16.0
1.0
1.5
17.0
1.0
1.5
19.0
1.2
1.6
23
1.2
1.8
28
• Current reduction coefficient
No. of wires in a tube Coefficient
Up to 3
4
5 or 6
7 to 15
16 to 40
41 to 60
61 or more
Max.
Minimum
conductor
Test
insulation
resistance
voltage
resistance
(20°C)
(V/1 min.)
(MW
(W/km)
9.42
1500
2500
5.30
1500
2500
3.40
1500
2500
2.36
1500
2000
1.34
2000
1500
0.849
2000
1500
0.491
2500
1500
1
2
0.70
0.63
0.56
0.49
3
0.43
0.39
0.34
4
(Reference)
Approx.
mass
km)
(kg/km)
170
250
5
360
475
730
1100
1800
6
7