Inertia ratio can be switched between No.1 and No.2 by the switching input (J-SEL). This
feature is useful in application where the load inertia changes in two steps.
Applicable Range
This function can be applicable only when the following conditions are satisfied.
Control mode
Others
Caution
• Be sure to change the inertia ratio while the motor is in stop state. Otherwise, vibration
or oscillation will occur.
• If the difference between the 1st inertial ratio and 2nd inertia ratio is large, vibration,
etc., may occur even in stop mode. These potential problems should be identified on the
actual model.
Related page
• P.3-30 "Inputs and outputs on connector X4"
5-36
5. Manual Gain Tuning (Application)
Inertia ratio switching function
Conditions under which the Inertia ratio switching function is activated
• Can be used in all control modes.
Pr0.01 = 0 : Position control
Pr0.01 = 1 : Velocity control
Pr0.01 = 2 : Torque control
Pr0.01 = 3 : Position/Velocity control
Pr0.01 = 4 : Position/Torque control
Pr0.01 = 5 : Velocity/Torque control
Pr0.01 = 6 : Full-closed control
• Should be in servo-on condition
• Input signals such as the deviation counter clear and command input
inhibit, and parameters except for controls such as torque limit setup, are
correctly set, assuring that the motor can run smoothly.
• Real-time auto-tuning should be disabled. (Pr0.02=0)
• Adaptive filter should be disabled. (Pr2.00=0)
• Instantaneous speed observer should be disabled. (Pr6.10=0)
• Disturbance observer should be disabled. (Pr6.24=0 bit1=0)
• P.4-4... , P.4-52, 53 "Details of parameter"