Chapter 16 Wireless System
6. Data for Automatic Wake-Up programming is canceled by Check Out operation.
7. The number of Automatic Wake-Up call attempts is programmable from one to five times.
8. If the station does not answer, is busy, in Line Lockout, or ringing, recalling is initiated one minute
later. Recalling is repeated up to five times. Each call that fails is printed. When the final attempt
results in failure, a buzzer is sounded at the printer and a flashing LED on the DSS/BLF Console is
available to indicate which station does not answer.
9. Call Forwarding and other features will not reroute Automatic Wake-Up calls.
Check In / Check Out
When this feature is activated, the following operations occur:
Check In:
Room Cutoff is cleared.
Check Out:
Room Status printout is supplied.
Do Not Disturb is reset.
Room Cutoff is set.
Message Waiting is reset.
Automatic Wake Up is cleared.
Multiline Terminals with LCD can be assigned as Hotel/Motel Front Desk Instruments. This feature can
only be activated from the Hotel/Motel Front Desk Instrument or the Property Management System
(PMS).
This feature only applies to guest room stations.
Instrument and Property Management System Features and Specifications for more information on
Check In/Check Out.
Note: When MP built-in PMS on IP is provided, you can set and cancel these hotel features only from PMS.
Direct Data Entry
This feature allows a maid or other hotel personnel to enter numeric data to the Property Management
System (PMS), using the guest room station for entry through dial operation. The same numerical data
can be output to a Hotel/Motel Printer by system data programming.
This feature is activated from a guest room telephone.
The digits 0, 1, 2, 3, 4, 5, 6, 7, 8, and 9 can be used for the input data.
The input data can be sent out to the PMS and/or Hotel/Motel Printer. The output option can be
selected by system data programming.
A maximum of 30 digits can be entered in one operation to the PMS and/or Hotel/Motel Printer. If data
exceeds 30 digits, the guest room station receives reorder tone.
If the input data to be sent is less than 30 digits, "#" can be used to end the digit string. (The "#" is not
sent to the PMS and Hotel/Motel Printer.)
Example: Access code + 1234567890#
Page 17-4
Refer to the Hotel/Motel Front Desk
NEAX2000 IPS Request for Proposal (RFP) Reference Guide