NEC NEAX 2000 IPS Reference Manual page 104

Request for proposal (rfp)
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

Chapter 5 Station Equipment
term
D
Series E Line Conditions
Terminal
DTP-8-1 TEL
DTP-8D-1 TEL
4DLC
DTP-16D-1 TEL
DTP-32D-1 TEL
DCU-60-1 Console
DTP-8-1 TEL
DTP-8D-1 TEL
8DLC
DTP-16D-1 TEL
DTP-32D-1 TEL
DCU-60-1 Console
DTP-8-1 TEL
DTP-8D-1 TEL
2DLCB/N
DTP-16D-1 TEL
DTP-32D-1 TEL
DCU-60-1 Console
Page 5- 28
Loop Resistance and Distance (Long Loop circuit built-in)
Maximum
Loop Resistance ( )
Cable Length
(24 AWG Cable)
(Without
ACA Unit)
35
1000 ft. (304 m)
35
1000 ft. (304 m)
26
650 ft. (198 m)
21
650 ft. (198 m)
N/A
N/A
35
1000 ft. (304 m)
35
1000 ft. (304 m)
26
650 ft. (198 m)
21
650 ft. (198 m)
N/A
N/A
35
2800 ft. (853 m)
35
2800 ft. (853 m)
26
2800 ft. (853 m)
21
2800 ft. (853 m)
N/A
N/A
NEAX2000 IPS Request For Proposal (RFP) Reference Guide
Cable Length
(24 AWG Cable)
(With ACA Unit)
4000 ft. (1219 m)
4000 ft. (1219 m)
4000 ft. (1219 m)
4000 ft. (1219 m)
1000 ft. (304 m)
1000 ft. (304 m)
1000 ft. (304 m)
1000 ft. (304 m)
1000 ft. (304 m)
1000 ft. (304 m)
4000 ft. (1219 m)
4000 ft. (1219 m)
4000 ft. (1219 m)
4000 ft. (1219 m)
2800 ft. (853 m)
NDA-24349 Issue 4