Night Connection - Fixed
This feature allows incoming calls normally
terminated to the Attendant to reroute to a
predetermined station when the system is placed
in Night Service.
Night Connection - Flexible
This feature provides incoming calls normally
terminated to the fixed night station to be Call
Forwarded to another station.
Trunk Answer Any Station (TAS)
This feature allows any station, other than one
with incoming restrictions, to answer incoming
calls when the system is in the night mode. When
this feature is activated, incoming exchange
network calls will activate a common alert signal at
the customer premises. By dialing a specified
code, any station may answer the call and then
extend it to any other station by means of the Call
Transfer feature.
Overflow for TAS Queue
If the TAS call is not answered by
predetermined time, the call will be forwarded
to predetermined station/Attendant
Console/Announcement Service.
Queue Limit for TAS
When a DID call is converted to TAS and the
number of using lines reaches queue limit,
this feature provides the system to restrict the
next call terminating.
Off-hook Alarm
This feature allows a station user to call the
Attendant, or a pre-designated station, by
simply staying off-hook for a preprogrammed
period of time. The calling number is
automatically displayed at the Attendant
Console, or the pre-designated station if
equipped with an LCD.
NEAX 2000 IPS Request for Proposal (RFP) Reference Guide
NDA-24349, Issue 4
Off-Premises Extensions
This feature allows the connection of a single
line telephone in an off-premises location. The
connection to the Off-Premises Extension can
be through direct copper or through the local
telephone company.
Open Application Interface (OAI)
Provides a computer-to-PBX interface,
allowing a computer to control the function of
the NEAX2000 IPS. The NEAX2000 IPS can
be customized to accommodate most
customer applications. Application software
can be provided by NECAM, an outside
software house, or a customer.
Optical Interface
The Optical Interface Card (PN-M10) provides
an internal optical fiber modem to the T1/E1
or Remote PIM network. The PN-M10
provides a bandwidth of 6.3 Mbps and
supports a maximum distance of 10
kilometers (or 6.25 miles) point to point. The
NEAX2000 IPS only supports Single Mode
optical fiber.
Pad Lock
This feature temporarily restricts telephones
from making unauthorized calls by dialing
special access code when station users are
away from their seats.
Periodic Time Indication Tone
This feature provides a periodic tone to the
station user who has made an outgoing call.
This feature can be allowed or denied for
each station.
Pooled Line Access
A line key can be assigned to access Pooled
Lines. Each line key will allow incoming,
outgoing, or both-way access to a trunk route.
Chapter 9 Descriptions