Resizing - Brother BAS-761 Instruction Manual

Programmer
Hide thumbs Also See for BAS-761:
Table of Contents

Advertisement

Resizing

Command to be used
8
8
8
M
F
M
This function is available only when the needle is at the home position.
The center point (reference point) of resizing is as follows.
X coordinate : Center of the outer shape of the data
Y coordinate : Uppermost position of the data
All the settings of attributes become invalid if the pattern is resized without changing the
stitch length. Set the attributes after resizing the pattern.
1.
Make sure that the needle is at the home position.
Press
if the needle is not at the home position.
R
2.
Input
8
8
8
Displays the number of the command input.
3.
Input the magnification in 3 digits in the X direction, then press
Magnification values of 0 - 400 are available for input.
Displays the number of the magnification input.
4.
Input the magnification in 3 digits in the Y direction, then press
Magnification values of 0 - 400 are available for input.
Displays the number of the magnification input.
5.
Input the stitch length in 3 digits, then press
If the value is "000", the stitch count remains unchanged. The stitch length increases or decreases.
Resizing a pattern in the X and Y directions
Used to input magnification in the X direction.
Values 90 to 110 % are available for resizing.
Used to input magnification in the Y direction.
Values 90 to 110 % are available for resizing.
.
M
Programmer
Chapter 3 Programming with Command Function
.
L
.
F
.
M
119