FS-C5016N

1-6-6 Drum section

(1) Detaching and refitting the drum unit

Procedure
1. Remove the developer unit (see previous
page).
2. Remove the each connector cover.
3. Remove the two connectors.
4. While releasing two release levers and then
remove the drum unit. (also 4 colors with the
same procedure, there is no order.)
1-6-12
Connector cover
(Cyan)
Connector cover
(Black)
Figure 1-6-15
Connectors
Release lever
Figure 1-6-16
Connector cover
(Magenta)
Connector cover
(Yellow)
Release lever
Drum unit
(Yellow)
(Magenta)
Drum unit
(Cyan)
(Black)