(4) Detaching and refitting the main high voltage PWB
Procedure
1. Remove the right cover (see page 1-6-3).
2. Unlatch the four latches and remove the one
connector and then remove the main high
voltage PWB.
3. Check or replace the main high voltage
PWB and then refit all the removed parts.
Latches
Connector
Figure 1-6-40
FS-C5016N
Main high voltage PWB
1-6-29