1-6-4 MP tray feed unit
(1) Detaching and refitting the MP tray feed unit
Procedure
1. Remove the paper feed unit (see page 1-6-
5).
2. Remove the paper right cover (see page 1-
6-3).
3. Remove the main high voltage PWB (see
page 1-6-29).
4. Remove the paper feed drive unit (see page
1-6-32).
5. While pushing the latch from inside the main
unit frame and then remove the MP tray feed
unit.
6. Check or replace the MP tray feed unit and
then refit all the removed parts.
MP tray feed unit
MP tray feed unit
Figure 1-6-12
FS-C5016N
Latch
1-6-9