FS-C5016N
Connector
Pin No.
CN1
1
AC100V
Connected
to the AC
2
-
inlet
3
AC100V
CN2
1
HEATER
Connected
LIVE
to the AC
2
NC
inlet fuser
3
HEATER
heater lamp
COM
1 and 2,
4
NC
fuser ther-
5
HEATER
mostat 1
LIVE
and 2
YC901
1
TH1
Connected
2
TH2
to the
3
FDSOLDR
engine con-
4
+5V2
troller PWB
5
RCOVOP*
6
FUSOLDR
7
EXITPAP*
8
+24V2
9
HEAT1DR
10
HEAT2DR
11
ZCROSS
12
SLEEP
13
24V1
14
24V1
15
24V1
16
24V1
17
GND
18
GND
19
GND
20
GND
21
GND
22
GND
23
GND
24
GND
25
+3.3V1
26
+3.3V1
27
+3.3V1
28
+3.3V1
29
+5V1
30
+5V1
YC902
1
GND
Connected
2
+24V2
to the fuser
3
FDDR
PWB
4
EXITPAP*
5
FUSOLDR
6
+5V1
6
RCOVOP*
7
TH1
8
TH2
2-3-2
Signal
I/O
Voltage
I
220 - 240 V AC
120 V AC
-
-
I
220 - 240 V AC
120 V AC
O
220 - 240 V AC
120 V AC
-
-
O
220 - 240 V AC
120 V AC
-
-
O
220 - 240 V AC
120 V AC
O
Analog
O
Analog
I
0/24 V DC
O
5 V DC
O
0/5 V DC
I
0/24 V DC
O
0/5 V DC
O
24 V DC
I
0/24 V DC
I
0/24 V DC
O
0/5 V DC (pulse)
I
0/24 V DC
O
24 V DC
O
24 V DC
O
24 V DC
O
24 V DC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
3.3 V DC
I
3.3 V DC
I
3.3 V DC
I
3.3 V DC
O
5 V DC
O
5 V DC
-
-
O
24 V DC
O
0/24 V DC
I
0/5 V DC
O
0/24 V DC
O
5 V DC
I
0/5 V DC
I
Analog
I
Analog
Description
AC power input
Ground
AC power output
Fuser heater lamp 1 output
Not Connected
Fuser heater lamps output (common)
Not Connected
Fuser heater lamp 2 output
Fuser thermistor 1 detection voltage output
Fuser thermistor 2 detection voltage output
Face up/down solenoid control signal
5 V DC power output
Rear cover open/close sensor: rear cover Open/
Close
Face up/down solenoid control signal
Exit sensor: On/Off
24 V DC power output
Fuser heater lamp 1: On/Off
Fuser heater lamp 2: On/Off
Zero cross signal output
Eco-mode control signal input: Normal/Eco-mode
24 V DC power output
24 V DC power output
24 V DC power output
24 V DC power output
Ground
Ground
Ground
Ground
Ground
Ground
Ground
Ground
3.3 V DC power input
3.3 V DC power input
3.3 V DC power input
3.3 V DC power input
5 V DC power output
5 V DC power output
Ground
24 V DC power output
Face up/down solenoid control signal
Exit sensor: On/Off
Face up/down solenoid control signal
5 V DC power output
Rear cover open/close sensor: rear cover Open/
Close
Fuser thermistor 1 detection voltage output
Fuser thermistor 2 detection voltage output