Kyocera Mita FS-C5016N - Color LED Printer Service Manual page 42

Service manual
Hide thumbs Also See for FS-C5016N - Color LED Printer:
Table of Contents

Advertisement

FS-C5016N
Service items
>>Maintenance
1-4-12
Counter reset for the maintenance kit
Description
The "Install MK" message means that maintenance kit should be replaced at 200,000 images
of printing. The interval counter must be manually reset using this service item.
MK-500/MK-502 Maintenance kit includes the following units:
MK-500 (For 220 - 240 V AC model)
• Drum unit: DK-500 [Part No.: 2D993040]
• Cyan developer unit: DV-500C [Part No.: 2D993080]
• Magenta developer unit: DV-500M [Part No.: 2D993070]
• Yellow developer unit: DV-500Y [Part No.: 2D993060]
• Black developer unit: DV-500K [Part No.: 2D993050]
• Fuser unit: FK-500 (E) [Part No.: 2D993150]
• Paper feed unit: FE-500 [Part No.: 2D993140]
• Primary transfer set: TR-500 [Part No.: 2D993130]
(Primary transfer unit and primary transfer cleaning unit [Part No.: 2D993250])
• Ozone filters × 2: [Part No.: 2D902530]
• Feed roller set:
Retard roller: [Part No.: 5AAVROLL+052]
MP tray feed roller: [Part No.: 5AAVROLL+051]
MK-502 (For 120 V AC model)
• Drum unit: DK-500 DRUM UNIT [Part No.: 2D993040]
• Cyan developer unit: DV-502C DLP C UNIT [Part No.: 2D993290]
• Magenta developer unit: DV-502M DLP M UNIT [Part No.: 2D993280]
• Yellow developer unit: DV-502Y DLP Y UNIT [Part No.: 2D993270]
• Black developer unit: DV-502K DLP K UNIT [Part No.: 2D993260]
• Fuser unit: FK-500 (U) FUSER UNIT [Part No.: 2D993220]
• Paper feed unit: FE-500 [Part No.: 2D993140]
• Primary transfer set: TR-500 [Part No.: 2D993130]
(Primary transfer unit and primary transfer cleaning unit [Part No.: 2D993250])
• Ozone filters × 2: [Part No.: 2D902530]
• Feed roller set:
Retard roller: [Part No.: 5AAVROLL+052]
MP tray feed roller: [Part No.: 5AAVROLL+051]
Purpose
To reset the life counter for the developer units and drum units included in maintenance kit.
Procedure for replacing the maintenance kit
1. Remove the four old drum units (See page 1-6-12).
2. Remove the LED print head from each old drum unit and then refit to the new drum unit
(See page 1-6-13).
3. Install the four new drum units.
4. Replace the four developer units (See page 1-6-11).
5. Replace the fuser unit (See page 1-6-18).
6. Replace the paper feed unit (See page 1-6-5).
7. Replace the primary transfer unit (See page 1-6-14).
8. Replace the primary transfer cleaning unit (See page 1-6-16).
9. Replace the two ozone filters (See page 1-6-35).
10. Replace the retard roller (See page 1-6-7).
11. Replace the MP tray feed roller (See page 1-6-10).
Start
Enter the service mode [>>Maintenance].
Press the ENTER key, ">>Maintenance ?" is displayed.
Press the ENTER key twice. The counter for each component is reset immediately.
Completion
Note:
Occurrences of resetting the maintenance kits are recorded on the service status page in
number of pages or images at which the maintenance kit was replaced (See page 1-4-4).
This may be used to determine the possibility that the counter was errorneously or uninten-
tionally reset.