Event Code: 812
Message:
CTP shutdown due to thermal violations
Severity:
Major
Explanation:
The CTP has been marked failed and power has been removed from the card because of excessive heat. This
event follows an indication that the CTP "hot" threshold level has been surpassed (event 811).
Action:
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 850
Message:
System shutdown due to CTP thermal violations
Severity:
Severe
Explanation:
The switch has been shutdown because of excessive thermal violations on the last operational CTP.
Action:
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
EFC Server
E-Mail
Call-Home
CMM Module Events (800 through 899)
Event Code Tables
Host
Sense Info
Link Incident
Host
Sense Info
Link Incident