McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 484

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Code Tables
B
Event Code: 440
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
B-40
Embedded Port hardware has failed
Major
The embedded port hardware detected an error.
Replace the switch. Perform a data collection operation for the switch using the EFC Manager, and return the
failed CTP card and the CD to McDATA for analysis and repair.
Byte 0 = Slot Position
Byte 1 = Reason Code
00 = TX clock loss
01 = Solicited response parity error detected
02 = Solicited response invalid error detected
03 = High availability error threshold exceeded
Bytes 4 - 7 = Elapsed millisecond tick count
Bytes 8 - 11 = High availability error callout (internally defined)