Messages
A
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
A-8
Action
Run diagnostics on an E-port only when it is not active.
Message
Cannot run diagnostics while a device is logged-in to the port.
Description
A device is logged in to the port where a diagnostic test is attempted.
Action
Log out the device and run the diagnostic test again.
Message
Cannot run diagnostics. The port is not installed.
Description
Port diagnostics cannot be performed when the port is not installed.
Action
Run diagnostics only on a port that is installed.
Message
Cannot save IPL configuration file while active=saved is enabled.
Description
The user cannot save the IPL file while the active=save property is
set.
Action
The FICON management server property, active=save, must be
disabled for EFCM to save the IPL file.
Message
Cannot save port configuration.
Description
Port configuration cannot be saved. The link is down or busy.
Action
Retry the operation later. If the condition persists, contact support
personnel.
Message
Cannot save SNMP configuration.
Description
SNMP configuration cannot be saved. The link is down or busy.
Action
Retry the operation later. If the condition persists, contact support
personnel.