Diagnostics
3
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
3-102
Did reconnecting the cable solve the problem and did both switches
join through the ISL to form a fabric?
NO
YES
The switches, associated ISL, and multiswitch fabric appear
operational.
16
Initial program load (IPL) the switch
page 4-43).
Did the IPL solve the problem and did both switches join through the
ISL to form a fabric?
NO
YES
The switches, associated ISL, and multiswitch fabric appear
operational.
Contact the next level of support.
17
The switch E_Port segmented because a response to a verification
check indicates the attached switch is not operational.
a. Perform the data collection procedure for the switch and return
the CD to McDATA for analysis.
b. Go to
MAP 0000: Start MAP
isolation for the failed switch.
18
Does the SANpilot interface appear operational?
YES
NO
Analysis for an Ethernet link, AC power distribution, or CTP
card failure is not described in this MAP. Go to
Start MAP
on page 3-6. If this is the second time at this step,
contact the next level of support.
19
Inspect the Fibre Channel port segmentation reason at the SANpilot
interface.
a. At the View panel, click the Port Properties tab. The View panel
(Port Properties tab) displays.
b. Click the port number (0 through 31) of the segmented port.
(Reset or IPL the Switch
on page 3-6 and perform fault
MAP 0000: