Event Code: 151
Message:
Fabric configuration failure.
Severity:
Informational.
Explanation:
A fabric-wide configuration activation process failed. An event code 151 is recorded only by the managing switch
in the fabric. The event code is intended to help engineering support personnel fault isolate a fabric-wide
configuration failures.
Action:
Perform the data collection procedure and return the CD to McDATA support personnel.
Event Data:
Event data are mapped from the software implementation of the FC-SW2 protocol and are typically complicated.
Decoding the event data requires engineering support. Event data are as follows:
Bytes 0 - 3 = Managing switch domain ID in internal format (1-31).
Bytes 4 - 7 = Fabric configuration operation that failed.
Bytes 8 - 11 = Fabric configuration step that failed.
Bytes 12 - 15 = Managed switch domain ID in internal format (1-31).
Bytes 16 - 19 = Response command code received from the managed switch.
Bytes 20 - 23 = Response code received from the managed switch.
Bytes 24 - 27 = Reason code received from the managed switch.
Bytes 28 - 31 = Error code received from the managed switch.
Distribution:
Switch
SANpilot
Event Log
System
Event Log
Error LED
EFC Server
E-Mail
Call-Home
System Events (000 through 199)
Event Code Tables
Host
Sense Info
Link Incident
B
B-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 3032Sphereon 3232

Table of Contents