McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 485

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Code: 442
Message:
Embedded Port Anomaly Detected
Severity:
Informational
Explanation:
Indicates that the control processor has detected a deviation in the normal operation mode or operation status of
the embedded port.
Action:
No action required. There will be an additional event generated if the occurrence of this incident exceeds an error
threshold resulting in a module or port failure.
Event Data:
Word 0:
Byte 0 = Embedded port number
Byte 1 = Reason Code (See following chart)
Word 1:
Byte 0 - 3 = Elapsed millisecond tick count
Word 2:
Byte 0 -1 = High availability error callout #1
Byte 2 - 3 = High availability error callout #2
Word 3:
Byte 0 = Detecting port
Byte 1 = Connected port
Byte 3 = Reserved
Word 4:
Byte 0 -1 = High availability error callout #3
Byte 2 - 3 = High availability error callout #4
Distribution:
Switch
Nonvolatile
System
Event Log
Event #442 Anomaly Reason Codes
Reason Code
Description
0x00
Utility bus error to SBAR
0x01
Utility bus error to Port Module
0x02
Reserved
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
Additional Data
HA Error Callouts (Words 2 & 4)
HA Error Callouts (Words 2 & 4)
HA Error Callouts (Words 2 & 4)
CTP Card Events (400 through 499)
Event Code Tables
Host
Sense Info
Link Incident
B