McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 237

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

41
Ensure the switch reporting the problem is connected to facility AC
power. Inspect the switch for indications of being powered on, such
as:
At the front panel, an illuminated PWR LED or ERR LED.
Green LEDs illuminated on the power supplies.
Audio emanations and airflow from fans.
Does the switch appear powered on?
YES
NO
A power distribution problem is indicated. Go to
Power Distribution Analysis
42
At the front of the switch, inspect the amber ERR LED.
Is the LED illuminated?
NOYES
A FRU failure or link incident is indicated. Go to
obtain event codes that identify the failure. Exit MAP.
43
Either a switch-to-PC Internet link problem (Internet too busy or IP
address typed incorrectly) or a CTP card failure is indicated.
a. Wait approximately five minutes, then attempt to login to the
switch again.
b. At the Netsite field (Netscape Navigator) or Address field
(Internet Explorer), type http://xxx.xxx.xxx.xxx, where
xxx.xxx.xxx.xxx is the IP address of the switch (obtained in
step
1). The Username and Password Required dialog box
appears.
c. Type the user name and password obtained in
OK. If the View panel does not display, wait another five minutes
and perform this step again.
MAP 0100:
on page 3-28.
step 52
step
1, and click
MAP 0000: Start MAP
Diagnostics
3
to
3-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 3032Sphereon 3232

Table of Contents