McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 297

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Select the McDATA Fabric 1.0 option if the switch is
fabric-attached only to other McDATA switches that are also
operating in McDATA Fabric 1.0 mode. Select the Open Fabric
1.0 option if the fabric contains OEM switches that are
open-fabric compliant.
c. Click the Activate button to save the selection and close the
dialog box.
Did configuring the management style solve the problem?
NO
YES
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
25
A loopback (wrap) plug is connected to the port and there is no
diagnostic test running. Is a loopback plug in the port receptacle?
YES
NO
Contact the next level of support. Exit MAP.
26
Remove the wrap plug from the port receptacle. If directed by the
customer, connect a fiber-optic jumper cable attaching a device to the
switch.
If the port is operational and a device is not attached, both LEDs
adjacent to the port extinguish and the port state is No Light.
If the port is operational and a device is attached, the green
LED illuminates, the amber LED extinguishes, and the port state
is Online.
Did removing the wrap plug solve the problem?
NO
YES
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
27
A port connection timed out because of an unresponsive device
(node) or an ISL connection was not allowed because of a security
violation (authorization failure reject). Check the port status and clean
the fiber-optic connectors on the cable.
MAP 0600: Port Failure and Link Incident Analysis