McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 240

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
3
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
3-26
Is a link incident or port problem indicated for any of the ports?
NO
YES
A link incident problem or port SFP failure is indicated. Go to
step 52
to obtain event codes. If no event codes are found,
go to
MAP 0600: Port Failure and Link Incident Analysis
page 3-72.
50
Inspect the power supply operational states.
a. At the View panel, click the Component Properties tab. The View
panel (Component Properties tab) displays.
b. Inspect the State fields for both power supplies.
Does the State field display a Failed message for either power
supply?
NO
YES
A power supply failure is indicated. Go to
codes. If no event codes are found, go to
Distribution Analysis
51
Inspect the State fields for Fan 0, and Fan 1 through Fan 3.
Does the State field display a Failed or Not Installed message for
any of the fans?
step 52
to obtain event
MAP 0100: Power
on page 3-28.