Diagnostics
3
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
3-74
Is an amber port LED illuminated but not blinking (beaconing)?
YES
NO
The switch appears operational, however a link incident
or other problem may have occurred. Perform fault isolation
at the EFC Server or customer-supplied server.
Go to
step
13.
6
As indicated by a message or event code 506, 512, or 514, a Fibre
Channel port failed and the SFP optical transceiver must be removed
and replaced. Refer to
RRP: SFP Transceiver
This procedure is concurrent and can be performed while the
switch is powered on and operational.
Verify location of the failed port.
Replace the optical transceiver with a transceiver of the same
type (shortwave or longwave).
Perform an external loopback test for the port as part of FRU
removal and replacement. Refer to
on page 4-22.
Did optical transceiver replacement solve the problem?
NO
YES
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
7
Is fault isolation being performed at the SANpilot interface?
YES
NO
Fault isolation is being performed at the EFC Server
(or customer-supplied server). Go to
8
Does the SANpilot interface appear operational?
NO
YES
Go to
step
11.
on page 5-2.