Clear Link Incident Alert(S) Dialog Box - McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
3
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
3-90
b. Select Clear Link Incident Alert(s). The Clear Link Incident
Alert(s) dialog box displays.

Clear Link Incident Alert(s) Dialog Box

Figure 3-43
c. Select the This port (n) only radio button (where n is the port
number) and click OK. The link incident clears.
d. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
NO
The problem is transient and the Fibre Channel link and
switch appear operational. Exit MAP.
35
Inspect the fiber-optic jumper cable attached to the port and ensure
the cable is not bent and connectors are not damaged. If the cable is
bent or connectors are damaged:
a. Notify the customer the port will be blocked. Ensure the
customer's system administrator quiesces Fibre Channel frame
traffic through the port and sets the attached device offline.
b. Block the port. Refer to
c. Remove and replace the fiber-optic jumper cable.
d. Unblock the port. Refer to
Was a corrective action performed?
YES
NO
Go to
36
Monitor port operation for approximately five minutes.
Did the link incident recur?
Block or Unblock a Port
Block or Unblock a Port
step
37.
on page 4-45.
on page 4-45.