Event Code Tables
B
Event Code: 421
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
B-34
Firmware download complete
Informational
A new version of the switch firmware was successfully downloaded from the EFC Server or from the SANpilot.
No action required
New firmware release level (ASCII) in the format: FF.MM.II BBBB
FF: Bytes 0-1 = Function release level
MM: Bytes 3-4 = Maintenance release level
II: Bytes 6-7 = Interim release level
BBBBB: Bytes 9-12 = Build ID
Example: 30 31 2E 30 32 2E 30 30 20 30 30 34 38 = Release 10.02.00 Build 0048
Notes:
Release format punctuation is incorporated in data and formatted in ASCII.
Only the first byte of word 3 is used.
Data is an array of bytes eliminating any LSB/MSB considerations.