McDATA 316095-B21 - StorageWorks Edge Switch 2/24 Installation And Service Manual page 506

Fabric switches
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Event Code Tables
B
Event Code: 582
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
B-62
Bit-error threshold exceeded
Major
The number of code violation errors recognized by the incident node has exceeded a threshold (see FC-PH
clause 5.1).
A Link-incident Record (LIR) is generated and sent to the host using the Link-Incident reporting procedure
defined in the T11/99-017v0 document. If, after fault isolation is performed by the host, it is determined that the
incident is because of a port failure, perform a data collection procedure for this switch using the EFC manager,
and return the CD to McDATA for analysis.
Byte 0 = Port number (00-8F)
Bytes 4-7 = Elapsed millisecond tick count.
Switch
Nonvolatile
System
System
Error
Event Log
Indicator
EFC Server
Event Log
E-Mail
Host
Call-Home
Sense Info
Link Incident

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 3032Sphereon 3232

Table of Contents