Event Code Tables
B
Event Code: 802
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
Event Code: 805
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
B-74
Port module shutdown due to thermal violations
Major
The Port Module has been marked failed and power has been removed from the board due to excessive heat.
This event follows an indication that the port module "hot" threshold level has been surpassed (event 801).
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
No supplementary data included with this event.
Switch
Nonvolatile
System
System
Error
Event Log
Indicator
High-temperature warning (SBAR module thermal sensor).
Major
The thermal sensor associated with the SBAR module has detected that the "warm" temperature threshold level
has been surpassed.
Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
No supplementary data included with this event.
Switch
Nonvolatile
System
System
Error
Event Log
Indicator
EFC Server
Event Log
E-Mail
EFC Server
Event Log
E-Mail
Host
Call-Home
Sense Info
Host
Call-Home
Sense Info
Link Incident
Link Incident

Hide quick links: