Diagnostics
3
.
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
3-16
Figure 3-5
Link Incident Log
If a link incident occurred, the affected port number is listed with one
of the following messages.
Link interface incident - implicit incident.
Link interface incident - bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence (NOS)
received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the
current link state.
Did one of the listed messages appear in the Link Incident Log?
YES
NO
The switch appears operational.
A link incident problem is indicated. Go to
codes. If no event codes are found, go to
Link Incident Analysis
step 23
MAP 0600: Port Failure and
on page 3-72.
to obtain event