Event Code Tables
B
Event Code: 208
Message:
Severity:
Explanation:
Action:
Event Data:
Distribution:
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
B-24
Power supply false shutdown
Major
The power supply indicated that it was about to shutdown as a result of a power loss, but never did. The
operational firmware prepared for the shutdown.
If subsequent power events occur, perform the data collection procedure for this unit using the EFC Manager,
and return the CD and the faulty power supply to McDATA for analysis and repair.
No supplementary data included with this event.
Switch
Nonvolatile
System
System
Error
Event Log
Indicator
EFC Server
Event Log
E-Mail
Host
Call-Home
Sense Info