Event Code: 201
Message:
Power supply DC voltage failure
Severity:
Major
Explanation:
The DC voltage has failed on the indicated power supply. This event can only occur when dual power supplies are
installed. The second supply automatically assumes the full load to continue providing uninterrupted system
power.
Action:
Replace the faulty power supply. Perform the data collection procedure for this unit using the EFC Manager, and
return the CD and the faulty power supply to McDATA for analysis and repair.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
Event Code: 202
Message:
Power supply thermal failure
Severity:
Major
Explanation:
The thermal sensor has been triggered on the indicated power supply. This event can only occur when dual
power supplies are installed. The second supply automatically assumes the full load to continue providing
uninterrupted system power.
Action:
Replace the faulty power supply. Perform the data collection procedure for this unit using the EFC Manager, and
return the CD and the faulty power supply to McDATA for analysis and repair.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
Nonvolatile
System
Event Log
System
Event Log
Error
Indicator
System
Event Log
Error
Indicator
EFC Server
E-Mail
Call-Home
EFC Server
E-Mail
Call-Home
Power Supply Events (200 through 299)
Event Code Tables
Host
Sense Info
Link Incident
Host
Sense Info
Link Incident
B
B-21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sphereon 3032Sphereon 3232

Table of Contents