System Environmental Specifications; Table 6. Environmental Specifications - Intel SC5400RA - Server System - 0 MB RAM User Manual

Server system
Hide thumbs Also See for SC5400RA - Server System - 0 MB RAM:
Table of Contents

Advertisement

System Environmental Specifications

Temperature
Acoustic Noise
Electrostatic discharge
116

Table 6. Environmental Specifications

Non-operating: -40 ° to 70 °C.
Operating: 10 ° to 35 °C; derated 0.5 °C for every 1000 ft. (305 m) to
a maximum of 10,000 ft.
Non-operating: 90% relative humidity (non-condensing) at 30 °C.
Humidity
Operating: 2.0 g, 11 msec, 1/2 sine
Shock
Packaged: Operational after an 18" free fall.
5.5 BA LWA idle; 6.3 BA LWA typical operating
Tested to 15 kilovolts (kV); no component damage.
(ESD)