System Environmental Specifications

The following table defines the system level operating and non-operating environmental limits.
Operating Temperature
Non-Operating Temperature
Non-Operating Humidity
Acoustic noise
Shock, operating
Shock, unpackaged
Vibration, unpackaged
Shock and vibration, packaged
ESD
System Cooling Requirement in BTU/Hr
Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock requirement
mentioned above through its own chassis development and system configuration. It is the responsibility of
the system integrator to determine the proper shock level of the board and system if the system integrator
chooses different system configuration or different chassis. Intel Corporation cannot be held responsible, if
components fail or the server board does not operate correctly when used outside any of its published
operating or non-operating limits.
Technical Reference
Table 4.
System Environmental Limits Summary
Parameter
+10°C to +35°C with the maximum rate of change not to
exceed 10°C per hour
-40°C to +70°C
90%, non-condensing at 35°C
Sound power: 7.0BA with hard disk drive stress only at room
ambient temperature (23 +/- 2°C)
Half sine,
2g
peak, 11 mSec
Trapezoidal, 25g, velocity change 205 inches/second (80
lbs to < 100 lbs)
5 Hz to 500 Hz, 2.20 g RMS random
ISTA (International Safe Transit Association) Test Procedure 3A
+/-12 KV except I/O port +/- 8 KV per Intel
Specification
1600 Watt Max – 5459 BTU/hour
2130 Watt Max – 7268 BTU/hour
Limits
®
Environmental Test
41