DP 400-W Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each
voltage. Ensure your loads do not exceed the combined total wattage of 400 W. For
information about calculating the power usage for your configuration, see "Calculating
Power Usage."
Table 7. DP 400-W Power Supply Output Capability
System Environmental Specifications
Table 8. System Environmental Specifications
Temperature
Non-operating
Operating
Humidity
Non-operating
Shock
Operating
Packaged
Acoustic noise
Electrostatic
discharge (ESD)
®
Intel
Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Maximum
Voltage
Current
+3.3 V
20 A
+5.0 V
20 A
+5 V Standby
2.5 A
+12.0 V1
16 A
+12.0 V2
16 A
-12.0 V
0.5 A
-40 ° to 70 °C.
10 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum of
10,000 ft.
50% to 90% relative humidity (non-condensing) at 35 °C.
2.0 g, 11 msec, Halfsine
Operational after an 18" free fall.
DP, BRP configurations - 5.5 BA LWA idle; 6.0 BA LWA typical operation
WS configuration - 4.8 BA LWA idle; 5.5 BA LWA typical operation
Air Discharge: 0 to 12.0 kV
Contact Discharge: 0 to 8.0kV
Technical Reference