  • Page 1 Intel Server System SR1630BC ® Technical Product Specification Intel order number E44588-005 Revision 1.5 March 2010 Enterprise Platforms and Services Division - Marketing...
  • Page 2: Revision History

    Updated memory description in “Table 1: System Feature Set”. January 2010 Remove S3 state option from the “Power/Sleep LED” section” Add one Note about management feature is not supported. March 2010 Adding support for Intel® Xeon® processors 5600 series Intel order number E44588-005 Revision 1.5...
  • Page 3 Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
  • Page 4: Table Of Contents

    Table of Contents Intel® Server System SR1630BC TPS Table of Contents Introduction..........................1 Chapter Outline ......................1 Server System Use Disclaimer ................1 Product Overview........................2 System Views ......................4 System Dimensions ....................4 System Components....................5 Hard Drive and Peripheral Bays.................. 7 Server Board Overview .....................
  • Page 5 Intel® Server System SR1630BC TPS Table of Contents Processor Air Duct and Air Baffle ................21 Peripheral and Hard Drive Support..................22 Optical Drive Support....................23 Hard Disk Drive Support ..................23 Front Control Panel........................ 24 6.1.1 Power / Sleep LED ....................25 6.1.2...
  • Page 6 List of Figures ® Figure 1. Intel Server System SR1630BC................... 4 ® Figure 2. Major System Components – Intel Server System SR1630BC ........5 Figure 3. Back Panel Features ..................... 6 ® Figure 4. Drive Bays – Intel Server System SR1630BC ............. 7 ®...
  • Page 7 Intel® Server System SR1630BC TPS List of Tables List of Tables Updated memory description in “Table 1: System Feature Set”........... ii Table 1. System Feature Set ......................2 ® Table 2. Intel Server System SR1630BC Dimensions ..............4 Table 3. Board Layout reference ....................9 ®...
  • Page 9: Introduction

    Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of supported components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions.
  • Page 10: Product Overview

    ® The Intel Server System SR1630BC is a 1U server system designed to support the Intel Server Board S5500BC. The server board and the system have features designed to support the high-density server market. This chapter provides a high-level overview of the system features.
  • Page 11 Intel 5500 IOH chipset. One 82567 Gigabit Network Connection that connects to the Gigabit LAN Connect ® Interface / LAN Connect Interface on the Intel ICH10R Two 10/100/1000 Base-TX Interfaces through RJ-45 connectors with integrated magnetics. Link and Speed LEDs on the RJ-45 Connector.
  • Page 12: System Views

    Intel® Server System SR1630BC TPS Product Overview System Views ® Figure 1. Intel Server System SR1630BC System Dimensions ® Table 2. Intel Server System SR1630BC Dimensions Height 1.7 inches Width without rails 16.9 inches Depth without CMA 20 inches Maximum weight...
  • Page 13: System Components

    Power supply Slimline optical drive ® Figure 2. Major System Components – Intel Server System SR1630BC Note: The I/O connector locations on the back of the chassis are pre-cut, making an I/O shield unnecessary. You must install the supplied EMI gasket to maintain electromagnetic interference (EMI) compliance levels.
  • Page 14: Figure 3. Back Panel Features

    Intel® Server System SR1630BC TPS Product Overview AC Power Connector NIC 2 Connector (10 / 100 / 1000 Mb) BMC Management Port Serial Port A USB Ports 6 and 7 Video Connector USB Ports 8 and 9 NIC 1 Connector (10 / 100 / 1000 Mb) PCI Express* Slot Figure 3.
  • Page 15: Hard Drive And Peripheral Bays

    (SATA) hard drives and one slimline optical device. Slimline optical drive bay Hard drive bay HDD0 (located under the slimline optical drive bay) Hard drive bay HDD1 ® Figure 4. Drive Bays – Intel Server System SR1630BC Revision 1.5 Intel order number E44588-005...
  • Page 16: Server Board Overview

    Intel® Server System SR1630BC TPS Product Overview Server Board Overview ® Figure 5. Intel Server Board S5500BC picture Intel order number E44588-005 Revision 1.5...
  • Page 17: 2.5.1 Server Board Connector And Component Layout

    Product Overview Intel® Server System SR1630BC TPS 2.5.1 Server Board Connector and Component Layout The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and a description is below the figure.
  • Page 18: Intel Light-Guided Diagnostic Led Locations

    Intel® Server System SR1630BC TPS Product Overview Description Description System fan 3 header Main power connector DIMM sockets for Channel A & B (Supports CPU_1) Power Supply Auxiliary Connector SSI 24-pin Front Panel connector System fan 2 header CPU_1 fan header CPU Power Connector ®...
  • Page 19: Riser Card

    Product Overview Intel® Server System SR1630BC TPS ® Table 4. Intel Light-Guided Diagnostic LED reference Description Description Post-Code Diagnostic LEDs Status LED System ID LED HDD LED System Fan 3 Fault LED 5 VSB LED DIMM Fault LED System Fan 2 Fault LED...
  • Page 20: Power Sub-System

    Intel® Server System SR1630BC TPS Power Sub-System Power Sub-System The power sub-system consists of one, non-redundant high efficiency 400-W power supply that supports a 1U rack mount server system. The power supply and the power supply sub-system will have six outputs: 3.3 V, 5 V, 12 V1, 12V2, -12 V, and 5 VSB. The input is auto-ranging and power factor corrected.
  • Page 21: Figure 9. Power Supply Mechanical Drawing

    Power Sub-System Intel® Server System SR1630BC TPS Figure 9. Power Supply Mechanical Drawing Notes: 1. All dimensions are in mm. 2. The tolerance of the 40 mm height dimension (marked with letter C) pertains to the metal case only. Revision 1.5...
  • Page 22: 3.2 Output Connectors

    Intel® Server System SR1630BC TPS Power Sub-System 3.2 Output Connectors The power supply has a cable harness with five power connectors used to power various platform sub-systems. The following table defines each power connector. Table 5. Cable Harness Definition Label...
  • Page 23: P3 - Power Signal Connector

    Power Sub-System Intel® Server System SR1630BC TPS Table 7. P2 – Processor/DDR3 Power Connector Pin-out Signal 18 Awg Color Signal 18 Awg Color Black +12V1 Yellow Black +12V1 Yellow Black +12V1 Yellow Black +12V1 Yellow 3.2.3 P3 – Power Signal Connector...
  • Page 24: P6 - Slim-Line Sata Optical Disk Drive Power Connector

    Intel® Server System SR1630BC TPS Power Sub-System 3.2.5 P6 – Slim-line SATA Optical Disk Drive Power Connector Connector housing: 6-pin SATA Power Contact: 15u plating minimum Table 10. P6 – Slim-line SATA Optical Disk Drive Power Connector Pin-out Signal 22 AWG Color Reserved N.C.
  • Page 25: Protection Circuits

    Power Sub-System Intel® Server System SR1630BC TPS Protection Circuits Protection circuits inside the power supply should cause only the power supply’s main outputs to shut down. If the power supply latches off due to a protection circuit tripping, an AC cycle off for 15 seconds and a PSON cycle high for 1 second should be able to reset the power supply.
  • Page 26: Over-Temperature Protection (Otp)

    Intel® Server System SR1630BC TPS Power Sub-System Output Voltage Minimum (V) Maximum (V) +12 V1,2 13.3 14.5 -12 V -13.3 -14.5 +5 VSB 3.5.3 Over-temperature Protection (OTP) The power supply is protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature.
  • Page 27: Cooling Sub-System

    Server System SR1630BC does not support redundant cooling. If a fan blower fails, you must power down the system as soon as possible so you can replace the failed fan blower. AF001524 ® Figure 11. Fan Module Assembly – Intel Server System SR1630BC Revision 1.5 Intel order number E44588-005...
  • Page 28: System Fan Connectors

    Intel® Server System SR1630BC TPS Cooling Sub-System Table 15. Cooling Zones Cooling Greatest Cooling Influence Zone System fan blower left CPU2 Primary cooling for CPU2, system memory, and PCIE card on riser card System fan blower right CPU1 Primary cooling for CPU1, IOH, and system memory 4.1.1...
  • Page 29: Power Supply Fans

    Processor Air Duct and Air Baffle The system requires the use of the system air duct to direct airflow and sustain appropriate air pressure. ® Figure 12. Air Duct for the Intel Server System SR1630BC Revision 1.5 Intel order number E44588-005...
  • Page 30: Peripheral And Hard Drive Support

    Intel® Server System SR1630BC TPS Peripheral and Hard Drive Support Peripheral and Hard Drive Support ® The Intel Server System SR1630BC provides support for two fixed hard drive bays and one slim-line peripheral drive bay at the front of the system. The fixed hard drive bays are designed to support SATA 3.5-inch drives.
  • Page 31: Optical Drive Support

    Peripheral and Hard Drive Support Intel® Server System SR1630BC TPS Optical Drive Support The system provides a slimline drive bay that you can configure for a SATA optical CD-ROM or a DVD / CD-R drive. Drives are mounted on a tray which allows for easy installation into and removal from the system.
  • Page 32: Front Control Panel

    ACPI-compliant operating system. Status LED System power LED Hard drive activity LED NIC 1 LED NIC 2 LED ® Figure 14. Front Control Panel – Intel Server System SR1630BC Table 17. Control Panel LED Functions Color State Description NIC Link/no access...
  • Page 33: Power / Sleep Led

    Front Control Panel Intel® Server System SR1630BC TPS Color State Description HDD access Green Random blink Disk Activity No hard disk activity The current limiting resistors for the power LED, system fault LED, and NIC LEDs are located ® on the Intel Server Board S5500BC.
  • Page 34: Drive Activity Led

    Intel® Server System SR1630BC TPS Front Control Panel Color State Criticality Description Non-fatal alarm – system is likely to fail: CATERR asserted. Critical temperature threshold asserted. Critical voltage threshold asserted. Amber Blink Non-critical Critical fan threshold asserted. VRD hot asserted.
  • Page 35: Pci Riser Cards And Assembly

    Front Control Panel Intel® Server System SR1630BC TPS PCI Riser Cards and Assembly ® The Intel Server Board S5500BC provides one PCI Express* x8 slot which supports one riser card with one riser card slot. The riser card supports one low-profile, half-length PCI Express* x8 add-in card which consumes power less than 15 W.
  • Page 36: Environmental And Regulatory Specifications

    5 Hz to 500 Hz, 2.20 g RMS random Shock, operating Half sine, 2 g peak, 11 mSec ESD* +/-15 KV except I/O port +/-8 KV per the Intel Environmental test specification System Cooling 2550 BTU/hour Requirement in BTU/Hr ®...
  • Page 37: Replacing The Cmos Battery

    Environmental and Regulatory Specifications Intel® Server System SR1630BC TPS Table 21. System Maintenance Procedure Times Activity Time Estimate Remove cover 1 min Remove and replace hard disk drive 5 min Remove and replace power supply module 1 min Remove and replace system fan...
  • Page 38: Product Regulatory Compliance

    URL: http://www.intel.com/go/serverbuilder If you do not have access to Intel’s Web address, please contact your local Intel representative. Server chassis (base chassis is provided with power supply and fans)⎯UL listed. Server board⎯you must use an Intel server board—UL recognized.
  • Page 39: Table 22. Product Safety & Electromagnetic (Emc) Compliance

    Environmental and Regulatory Specifications Intel® Server System SR1630BC TPS ® Note: The Intel Server System SR1630BC meets Class A Certifications Emissions requirements. Table 22. Product Safety & Electromagnetic (EMC) Compliance Compliance Regional Compliance Compliance Reference Marking Example Description Reference Australia / New Zealand...
  • Page 40 Intel® Server System SR1630BC TPS Environmental and Regulatory Specifications Compliance Regional Compliance Compliance Reference Marking Example Description Reference Korea RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) 인증번호: CPU-Model Name (A) Russia GOST-R Certification GOST R 29216-91 (Emissions)
  • Page 41: Electromagnetic Compatibility Notices

    Environmental and Regulatory Specifications Intel® Server System SR1630BC TPS Electromagnetic Compatibility Notices 8.6.1 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 42: Fcc Verification Statement

    Intel® Server System SR1630BC TPS Environmental and Regulatory Specifications 8.6.2 FCC Verification Statement Product Type: SR1630; S5500BC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 43: Rrl (Korea)

    The CCC Certification Marking and EMC warning is located on the outside rear area of the product. Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel’s product ecology compliance criteria.
  • Page 44: Table 23. Product Ecology Compliance Reference Table

    Not applied to internal packaging such as plastics, foams, etc. Intel Internal All materials, parts and subassemblies must not Specification contain restricted materials as defined in Intel’s Environmental Product Content Specification of None Required Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm...
  • Page 45 Compliance Reference Description Marking Example Intel Internal All materials, parts and subassemblies must not Specification contain restricted materials as defined in Intel’s Environmental Product Content Specification of None Required Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm International ISO11469 - Plastic parts weighing >25gm are intended to be marked with per ISO11469.
  • Page 46: Other Markings

    Intel® Server System SR1630BC TPS Environmental and Regulatory Specifications Other Markings Compliance Compliance Reference Compliance Reference Description Marking Example Stand-by Power 60950 Safety Requirement Applied to product is stand-by power switch is used. English: Multiple Power Cords 60950 Safety Requirement...
  • Page 47: Appendix A: Integration And Usage Tips

    Appendix A: Integration and Usage Tips Intel® Server System SR1630BC TPS Appendix A: Integration and Usage Tips ® This section provides a list of useful information unique to the Intel Server System SR1630BC that you should keep in mind while integrating the server system. •...
  • Page 48: Appendix B: Post Code Diagnostic Led Decoder

    Intel® Server System SR1630BC TPS Appendix B: POST Code Diagnostic LED Decoder Appendix B: POST Code Diagnostic LED Decoder The BIOS executes platform configuration processes during the system boot. Each process is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code on the POST Code Diagnostic LEDs on the back edge of the server board.
  • Page 49: Table 25. Diagnostic Led Post Code Decoder

    Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1630BC TPS Table 25. Diagnostic LED POST Code Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description Multi-use code – This POST Code is used in different contexts...
  • Page 50 Intel® Server System SR1630BC TPS Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description 0x52h Hot Plug PCI controller initialization 0x53h Reserved for PCI bus 0x54h Reserved for PCI bus...
  • Page 51 Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1630BC TPS Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description 0xD5 Trying to boot device selection 5 0xD6 Trying to boot device selection 6 0Xd7...
  • Page 52: Appendix C: Post Error Messages And Handling

    Intel® Server System SR1630BC TPS Appendix C: POST Error Messages and Handling Appendix C: POST Error Messages and Handling Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information.
  • Page 53 Appendix C: POST Error Messages and Handling Intel® Server System SR1630BC TPS Error Code Error Message Response 0195 Processor 0x Intel(R) QPI speed mismatch. Major 0196 Processor 0x model mismatch. Fatal 0197 Processor 0x speeds mismatched. Fatal 0198 Processor 0x family is not supported.
  • Page 54 Intel® Server System SR1630BC TPS Appendix C: POST Error Messages and Handling Error Code Error Message Response 854B DIMM_F2 Disabled. Major 8560 DIMM_A1 Component encountered a Serial Presence Detection (SPD) fail error. Major 8561 DIMM_A2 Component encountered a Serial Presence Detection (SPD) fail error.
  • Page 55: Table 29. Post Error Beep Codes

    Appendix C: POST Error Messages and Handling Intel® Server System SR1630BC TPS Error Code Error Message Response 9506 ATA/ATPI component encountered a controller error. Minor 95A6 PCI component encountered a controller error. Minor 95A7 PCI component encountered a read error.
  • Page 56 Intel® Server System SR1630BC TPS Appendix C: POST Error Messages and Handling In case of POST error(s) listed as Major, the BIOS enters the error manager and waits for the user to press an appropriate key before booting the operating system or entering the BIOS Setup.
  • Page 57: Glossary

    Glossary Intel® Server System SR1630BC TPS Glossary Word / Acronym Definition Australian Communication Authority ANSI American National Standards Institute Baseboard Management Controller CMOS Complementary Metal Oxide Silicon DC-to-DC Emergency Management Port Front Panel Fault Resilient Boot Field Replaceable Unit Liquid Crystal Display...
  • Page 58: Reference Documents

    Intel® Server System SR1630BC TPS Reference Documents Reference Documents See the following documents for additional information: • ® Intel Server Board S5500BC Technical Product Specification • ® ® ® Intel Server Board S5500BC / Intel Server Chassis SC5650 / Intel...

Table of Contents